Medtronic Micra Transcatheter Pacing System (TPS)

Category:

In Stock

Specifications

  1. Physical Characteristics:
    • Size: Approximately 1/10th the size of a conventional pacemaker (26 mm in length, 6.7 mm in diameter).
    • Weight: 2 grams.
    • Material: Biocompatible materials with a nitinol frame.
  2. Battery Life:
    • Estimated to last up to 12 years, depending on pacing needs.
  3. Placement:
    • Implanted directly into the right ventricle of the heart using a catheter-based procedure through the femoral vein.
  4. Pacing Technology:
    • Rate-responsive pacing: Automatically adjusts the pacing rate based on physical activity.
    • Single-chamber pacing: For patients requiring pacing in the right ventricle only.
    • Programmable settings allow for precise customization to meet individual patient needs.
  5. MRI Compatibility:
    • MRI Conditional: Safe for MRI scans under specified conditions.
  6. Connectivity:
    • Wireless communication via Medtronic CareLinkā„¢ for remote monitoring and programming.
  7. Anchoring System:
    • Flexible tines made of nitinol securely attach the device to the heart wall to prevent migration or displacement.

 

Description

Medtronic Micra Transcatheter Pacing System (TPS)

      1. Leadless Design:
        • No leads or surgical pocket eliminates common complications like infections, lead fractures, or venous obstruction.
      2. Minimally Invasive Procedure:
        • Implantation via catheterization reduces recovery time compared to traditional pacemaker surgeries.
      3. Cosmetic Advantage:
        • Completely contained within the heart, leaving no visible scars or protrusions under the skin.
      4. Self-Contained System:
        • Houses the battery, electronics, and electrodes in a single capsule.
      5. Low Risk of Complications:
        • Significantly reduces the risk of infection and complications associated with traditional pacemakers.
      6. Automatic Diagnostics:
        • Continuously monitors heart performance and device status, alerting healthcare providers to potential issues.
      7. Indications:
        • Patients with bradycardia requiring single-chamber ventricular pacing.
        • Suitable for those at higher risk of infection or with vascular access issues.

      Patient Benefits

      • Reduced procedural risks.
      • Faster recovery and minimal post-implantation restrictions.
      • No external components to maintain.

      The Medtronic Micra TPS represents a breakthrough in pacemaker technology by combining high efficacy with patient-friendly design and fewer complications.

Request for a Quote

Request a Quote
Please enable JavaScript in your browser to complete this form.
Name